Learn What A Type J Thermocouple Is Used For

By Claudette Lambert


There are several kinds of thermocouples available on the market today; these are all distinguished by means of charts and color coding. However there are four common calibrations, namely; K, J, E and T. Each one of these calibrations has a specific temperature range suited to their requirements and usage. The type J thermocouple is specifically used for any legacy temperature recordings and mainly found on control equipment.

Uses for J-thermocouples range from general functions to immersion in fluid and exposure to both air as well as gas. This product may also be custom made for usage in malleable solid infiltration and exterior or air temperature levels. As with the majority of thermocouples, these j-types could additionally be fitted inside connectors of either standard or miniature sizes.

Because the j-kind has a constricted temperature measuring range from approximately -40, to about 750 degrees C, it is not as sought after as the K-series couplers. Subsequently, not only is their lower temperature measuring range a deterrent for popularity, but their iron element makes them sensitive to quicker oxidization. Typically they are comprised of copper-nickel as well as iron alloys, their positive wires are iron alloy while the negative wires are copper-nickel alloy; the plus is that they are cheaper and much more accessible.

Of course it is vitally important to install the correct wiring for each specific junction and should suit the purpose for which they are being used. Basically one should not mix various types of wires as all of the thermocouple's wires are sensitive to polarity. It is thus just as vital to match colored wires when splicing them, one should bear in mind that both K and J-type couplet wires have a red negative wire.

Careful attention should also be paid to any outside sources of errors that will possibly impact their overall measurements or reading accuracy. Output signals are in milli- volt measurements and generally one will find they have small voltage to temperature sensitivity. Therefore the foremost sources of error for defined measurements to allow for are thermocouple malfunctions, noise errors and gain errors, accuracy balance as well as cold-junction return.

These diminutive temperature gauges are made by the welding of two metals to one another. Forces generated by the variations in hot and cold at the fusion point creates electromotive forces. It is commonly called the Seebeck effect and is still the more popular method of measuring temperatures.

In order to eliminate possible errors the manufacturers have a configuration guide that will ensure that all components are used for the correct application. Furthermore, they also offer technical support from expert engineers for any clients. Guidelines seem to be similar but there may be slight differences between manufacturers.

Specific thermocouples should have exclusive control programs designed to ensure all readings are truthful. Recalibration does occur when the thermocouple material is altered during any type of magnetic sway or really high temperatures. It must be stipulated that type j thermocouple is not suitable for any type of application where temperatures exceed 760 degrees C.